Utilidad del tromboelastograma en pediatría: correlación con pruebas habituales de la coagulación

dc.catalogadoraba
dc.contributor.authorSepúlveda Varela, Pablo Andrés
dc.contributor.authorSalgado, Andrea P.
dc.contributor.authorBarriga Gonzaga, José Eduardo
dc.contributor.authorToso, Alberto
dc.contributor.authorRojas B., Felipe
dc.contributor.authorAguirre Rioseco, Noemí Doris
dc.contributor.authorZúñiga Contreras, Pamela Alejandra
dc.date.accessioned2024-01-17T19:36:07Z
dc.date.available2024-01-17T19:36:07Z
dc.date.issued2019
dc.description.abstractLos exámenes habituales de coagulación evalúan distintos elementos de la hemostasia en forma parcial, y no traducen las interacciones celulares, lo que es especialmente sensible en pacientes críticos.Las técnicas viscoelásticas, como el tromboelastograma (TEG) muestran el proceso de coagulacióncompleto, y están siendo evaluadas como exámenes de la coagulación global. Objetivo: determinarla correlación de los exámenes habituales de coagulación con los valores del TEG, en niños atendidosen una unidad de cuidados intensivos (UCI). Pacientes y Método: Se revisaron 238 TEG de pacientes<18 años, con evidencia de alteración de coagulación clínica y/o de laboratorio, hospitalizados en UCI. Se correlacionaron los valores de los parámetros del TEG con cada uno de los valores de los exámenes habituales de coagulación. Los exámenes se obtuvieron según protocolo, utilizando una muestra de sangre de 4,5 ml para TEG con equipo TEG® 5000 Thrombelastograph Hemostasis System, mediante un transductor electromagnético que permite la medición de la resistencia durante la formación y lisis del coágulo. El recuento de plaquetas se obtuvo utilizando método automatizado o microscopía con contraste de fase; el fibrinógeno, tiempo de protrombina y de tromboplastina parcial activada por métodos nefelométricos. Resultados: 201 TEGs correspondientes a 59 pacientes.Se evidenció una correlación moderada a baja en todos los parámetros medidos. No se encontró correlación entre porcentaje de lisis del coágulo, ni firmeza del coágulo. Conclusiones: Existe una baja correlación entre la información entregada por TEG y los exámenes de coagulación habituales, esto sugiere que el TEG aporta información diferente acerca del estado de coagulación de los pacientes críticos evaluados.
dc.description.abstractIntroduction: Usual coagulation tests partially evaluate different elements of hemostasis, and do not translate cell interactions, which is an especially sensitive issue in critically ill patients. Viscoelastic measurement techniques, such as thromboelastogram (TEG) show the complete coagulation process and are being evaluated as global coagulation tests. Objective: To determine the correlation of the usual coagulation tests with the TEG values, in children treated in an intensive care unit (ICU). Patients and Method: We reviewed 238 TEGs of patients under 18 years of age, with evidence of clinical and/or laboratory coagulation alterations, who were hospitalized in the ICU. The TEG parameter values were correlated with each of the usual coagulation test values. The tests were obtained according to the protocol, using a 4.5 ml blood sample for TEG with TEG (R) 5000 Thrombelastograph Hemostasis System, through an electromagnetic transducer that allows the measurement of resistance during the clot formation and lysis. Platelet count was obtained using an automated method or phase-contrast microscopy, and fibrinogen levels, prothrombin time, and partial thromboplastin time activated by nephelometric methods. Results: 201 TEGs corresponding to 59 patients were reviewed. A moderate to low correlation was observed in all the measured parameters. No correlation was found between the percentages of clot lysis or clot firmness. Conclusions: There is a low correlation between the information provided by TEG and the usual coagulation tests. This suggests that the TEG provides different information about the coagulation status of the evaluated critical patients.
dc.fechaingreso.objetodigital2024-01-19
dc.format.extent7 páginas
dc.fuente.origenORCID-ene24
dc.identifier.doi10.32641/rchped.v90i6.930
dc.identifier.eissn0717-6228
dc.identifier.issn0370-4106
dc.identifier.pubmedidMEDLINE:32186584
dc.identifier.scopusidSCOPUS_ID:85078130601
dc.identifier.urihttps://doi.org/10.32641/rchped.v90i6.930
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/80581
dc.identifier.wosidWOS:000505610800006
dc.information.autorucEscuela de Medicina; Sepulveda Varela Pablo Andres; 0000-0001-7027-6473; 1095919
dc.information.autorucEscuela de Medicina; Barriga Gonzaga, José Eduardo; 0000-0003-2795-144X; 199864
dc.information.autorucEscuela de Medicina; Toso, Alberto; 0000-0002-3809-2567; 238020
dc.information.autorucEscuela de Medicina; Aguirre Rioseco, Noemí Doris; 0000-0003-3529-5702; 218585
dc.information.autorucEscuela de Medicina; Zúñiga Contreras, Pamela Alejandra; 0000-0003-0467-7513; 115760
dc.issue.numero6
dc.language.isoes
dc.language.isoen
dc.nota.accesoContenido completo
dc.pagina.final623
dc.pagina.inicio617
dc.revistaRevista Chilena de Pediatría
dc.rightsacceso abierto
dc.rights.licenseCC BY 4.0 DEEDAttribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectTromboelastograma
dc.subjectCoagulopatías
dc.subjectTEG
dc.subjectNiños
dc.subjectThromboelastography
dc.subjectCoagulopathy
dc.subjectTEG
dc.subjectChildren
dc.subjectMANAGEMENT
dc.subjectHEMOSTASIS
dc.subject.ddc610
dc.subject.deweyMedicina y saludes_ES
dc.subject.ods03 Good Health and Well-being
dc.subject.odspa03 Salud y bienestar
dc.titleUtilidad del tromboelastograma en pediatría: correlación con pruebas habituales de la coagulación
dc.title.alternativeUsefulness of the thromboelastogram in children: correlation with habitual coagulation tests
dc.typeartículo
dc.volumen90
sipa.codpersvinculados1095919
sipa.codpersvinculados199864
sipa.codpersvinculados238020
sipa.codpersvinculados218585
sipa.codpersvinculados115760
sipa.indexWoS
sipa.indexPubmed
sipa.indexSCOPUS
sipa.indexScielo
sipa.indexmedẽs
sipa.indexLatindex
sipa.trazabilidadORCID;2024-01-08
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
en_0370-4106-rcp-rchped-v90i6-930.pdf
Size:
447.03 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
0370-4106-rcp-rchped-v90i6-930.pdf
Size:
778.25 KB
Format:
Adobe Portable Document Format
Description: