Empirical model for dissolved oxygen depletion during corrosion of drinking water copper pipes

dc.contributor.authorVargas, Ignacio T.
dc.contributor.authorPasten, Pablo A.
dc.contributor.authorPizarro, Gonzalo E.
dc.date.accessioned2024-01-10T13:12:42Z
dc.date.available2024-01-10T13:12:42Z
dc.date.issued2010
dc.description.abstractPredictive models characterizing the evolution and interaction of key parameters of water chemistry are needed to better understand corrosion events in drinking water pipes. We performed experiments with new copper pipes under combinations of pH, dissolved oxygen (DO), temperature, chlorine, and dissolved inorganic carbon. We found that DO consumption during 24 h of stagnation was not limited by diffusion, thus the DO consumption rate in the bulk water could be used to probe the processes occurring at the pipe surface. We propose a quantitative dependency of the DO consumption rate on a rather limited set of physicochemical parameters. (C) 2010 Elsevier Ltd. All rights reserved.
dc.description.funderCONICYT
dc.description.funderFONDECYT
dc.fechaingreso.objetodigital2024-04-02
dc.format.extent8 páginas
dc.fuente.origenWOS
dc.identifier.doi10.1016/j.corsci.2010.03.009
dc.identifier.eissn1879-0496
dc.identifier.issn0010-938X
dc.identifier.urihttps://doi.org/10.1016/j.corsci.2010.03.009
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/78220
dc.identifier.wosidWOS:000279130600005
dc.information.autorucIngeniería;Pastén PA;S/I;87432
dc.information.autorucIngeniería;Pizarro GE;S/I;83223
dc.information.autorucIngeniería;Vargas IT;S/I;17080
dc.issue.numero7
dc.language.isoen
dc.nota.accesocontenido parcial
dc.pagina.final2257
dc.pagina.inicio2250
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.revistaCORROSION SCIENCE
dc.rightsacceso restringido
dc.subjectCopper
dc.subjectSEM
dc.subjectXRD
dc.subjectBY-PRODUCT RELEASE
dc.subjectPITTING CORROSION
dc.subjectGENERAL CORROSION
dc.subjectTEMPERATURE
dc.subjectSTAGNATION
dc.subjectCHLORINE
dc.subjectALUMINUM
dc.subjectEVENTS
dc.subjectPH
dc.titleEmpirical model for dissolved oxygen depletion during corrosion of drinking water copper pipes
dc.typeartículo
dc.volumen52
sipa.codpersvinculados87432
sipa.codpersvinculados83223
sipa.codpersvinculados17080
sipa.indexWOS
sipa.indexScopus
sipa.trazabilidadCarga SIPA;09-01-2024
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Empirical model for dissolved oxygen depletion during corrosion of drinking water copper pipes.pdf
Size:
2.43 KB
Format:
Adobe Portable Document Format
Description: