Inversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order

dc.catalogadorgrr
dc.contributor.authorCraft, J.
dc.contributor.authorWeber, J.
dc.contributor.authorLi;Y.
dc.contributor.authorCheng, J.Y.
dc.contributor.authorDiaz , N.
dc.contributor.authorKunze, K.P.
dc.contributor.authorSchmidt, M.
dc.contributor.authorGrgas, M.
dc.contributor.authorWeber, S.
dc.contributor.authorTang, J.
dc.contributor.authorParikh, R.
dc.contributor.authorOnuegbu, A.
dc.contributor.authorYamashita, A.-M.
dc.contributor.authorHaag, E.
dc.contributor.authorFuentes, D.
dc.contributor.authorCzipo, M.
dc.contributor.authorNeji, R.
dc.contributor.authorEspada, C.B.
dc.contributor.authorPrieto Vasquez, Claudia Del Carmen
dc.contributor.authorBotnar, Rene Michael
dc.date.accessioned2024-07-18T20:42:05Z
dc.date.available2024-07-18T20:42:05Z
dc.date.issued2024
dc.description.abstractContrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using.15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52–0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR. Graphical Abstract: (Figure presented.)
dc.fechaingreso.objetodigital2024-09-05
dc.fuente.origenORCID
dc.identifier.doi10.1007/s10554-024-03111-0
dc.identifier.eissn1875-8312
dc.identifier.issn1569-5794
dc.identifier.pubmedid38676848
dc.identifier.scopusidSCOPUS_ID:85191395012
dc.identifier.urihttps://doi.org/10.1007/s10554-024-03111-0
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/87135
dc.identifier.wosidWOS:001208819300002
dc.information.autorucEscuela de Ingeniería; Prieto Vasquez, Claudia Del Carmen; 0000-0003-4602-2523; 14195
dc.information.autorucInstituto de Ingeniería Biológica y Médica; Botnar, Rene Michael; 0000-0003-2811-2509; 1015313
dc.language.isoen
dc.nota.accesocontenido parcial
dc.pagina.final1376
dc.pagina.inicio1363
dc.publisherSpringer Science and Business Media B.V.
dc.revistaInternational Journal of Cardiovascular Imaging
dc.rightsacceso restringido
dc.subjectAtrial fibrillation
dc.subjectImage based navigators
dc.subjectLeft atrial delayed enhancement
dc.subjectMagnetic resonance angiography
dc.subjectVariable density cartesian sampling
dc.subject.ddc610
dc.subject.deweyMedicina y saludes_ES
dc.subject.ods03 Good health and well-being
dc.subject.odspa03 Salud y bienestar
dc.titleInversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order
dc.typeartículo
dc.volumen40
sipa.codpersvinculados14195
sipa.codpersvinculados1015313
sipa.trazabilidadSCOPUS;2024-05-05
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Inversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order.pdf
Size:
3.34 KB
Format:
Adobe Portable Document Format
Description: