Inversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order
dc.catalogador | grr | |
dc.contributor.author | Craft, J. | |
dc.contributor.author | Weber, J. | |
dc.contributor.author | Li;Y. | |
dc.contributor.author | Cheng, J.Y. | |
dc.contributor.author | Diaz , N. | |
dc.contributor.author | Kunze, K.P. | |
dc.contributor.author | Schmidt, M. | |
dc.contributor.author | Grgas, M. | |
dc.contributor.author | Weber, S. | |
dc.contributor.author | Tang, J. | |
dc.contributor.author | Parikh, R. | |
dc.contributor.author | Onuegbu, A. | |
dc.contributor.author | Yamashita, A.-M. | |
dc.contributor.author | Haag, E. | |
dc.contributor.author | Fuentes, D. | |
dc.contributor.author | Czipo, M. | |
dc.contributor.author | Neji, R. | |
dc.contributor.author | Espada, C.B. | |
dc.contributor.author | Prieto Vasquez, Claudia Del Carmen | |
dc.contributor.author | Botnar, Rene Michael | |
dc.date.accessioned | 2024-07-18T20:42:05Z | |
dc.date.available | 2024-07-18T20:42:05Z | |
dc.date.issued | 2024 | |
dc.description.abstract | Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using.15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52–0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR. Graphical Abstract: (Figure presented.) | |
dc.fechaingreso.objetodigital | 2024-09-05 | |
dc.fuente.origen | ORCID | |
dc.identifier.doi | 10.1007/s10554-024-03111-0 | |
dc.identifier.eissn | 1875-8312 | |
dc.identifier.issn | 1569-5794 | |
dc.identifier.pubmedid | 38676848 | |
dc.identifier.scopusid | SCOPUS_ID:85191395012 | |
dc.identifier.uri | https://doi.org/10.1007/s10554-024-03111-0 | |
dc.identifier.uri | https://repositorio.uc.cl/handle/11534/87135 | |
dc.identifier.wosid | WOS:001208819300002 | |
dc.information.autoruc | Escuela de Ingeniería; Prieto Vasquez, Claudia Del Carmen; 0000-0003-4602-2523; 14195 | |
dc.information.autoruc | Instituto de Ingeniería Biológica y Médica; Botnar, Rene Michael; 0000-0003-2811-2509; 1015313 | |
dc.language.iso | en | |
dc.nota.acceso | contenido parcial | |
dc.pagina.final | 1376 | |
dc.pagina.inicio | 1363 | |
dc.publisher | Springer Science and Business Media B.V. | |
dc.revista | International Journal of Cardiovascular Imaging | |
dc.rights | acceso restringido | |
dc.subject | Atrial fibrillation | |
dc.subject | Image based navigators | |
dc.subject | Left atrial delayed enhancement | |
dc.subject | Magnetic resonance angiography | |
dc.subject | Variable density cartesian sampling | |
dc.subject.ddc | 610 | |
dc.subject.dewey | Medicina y salud | es_ES |
dc.subject.ods | 03 Good health and well-being | |
dc.subject.odspa | 03 Salud y bienestar | |
dc.title | Inversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order | |
dc.type | artículo | |
dc.volumen | 40 | |
sipa.codpersvinculados | 14195 | |
sipa.codpersvinculados | 1015313 | |
sipa.trazabilidad | SCOPUS;2024-05-05 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Inversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order.pdf
- Size:
- 3.34 KB
- Format:
- Adobe Portable Document Format
- Description: