Kinematic limit analysis of Basilica del Salvador, a significant example of the neo-gothic architecture in Santiago, Chile

dc.catalogadorpau
dc.contributor.authorPalazzi Chiara, Nuria
dc.contributor.authorRovero, Luisa
dc.contributor.authorTonietti, Hugo
dc.contributor.authorLlera Martin, Juan Carlos de la
dc.contributor.authorSandoval Mandujano, Cristián
dc.date.accessioned2023-01-12T13:48:13Z
dc.date.available2023-01-12T13:48:13Z
dc.description.abstractThe Basilica del Salvador, located in Santiago city, is one of the most significant examples of the Chilean Neogothic architecture. Its current state of damage shows several local collapses caused by the March 3rd, 1985 central Chile earthquake, and the February 27th, 2010 Maule earthquake. As part of an ongoing research, this paper investigates the seismic behaviour of the church through the kinematic limit analyses. For this purpose, the main collapse mechanisms have been identified and analyzed. The results show that the seismic response is unsatisfactory and shows the inadequacy of the seismic performance of this constructional typology in a highly seismic context, due to the extremely slenderness of the structural elements and to the absence of box-behaviour, making it particularly sensitive to earthquake loading. It should be noted that these preliminary results are part of an ongoing research about the seismic retrofit of Basilica del Salvador.
dc.fechaingreso.objetodigital2023-01-11
dc.format.extent12 páginas
dc.fuente.origenSIPA
dc.identifier.urihttps://siberrisk.ing.puc.cl/wp-content/uploads/2018/07/16ECEE-Palazzi-et-al-Kinematic-limit-analysis-of-Basilica-del-Salvador.pdf
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/66248
dc.information.autorucEscuela de Ingeniería; Llera Martin, Juan Carlos de la; 0000-0002-9064-0938; 53086
dc.information.autorucEscuela de Ingeniería; Palazzi Chiara, Nuria; S/I; 1084480
dc.information.autorucEscuela de Ingeniería; Sandoval Mandujano, Cristián; 0000-0002-3639-5126; 1010864
dc.language.isoen
dc.nota.accesoContenido completo
dc.relation.ispartofEuropean Conference on Earthquake Engineering (16° : 2018 ; Thessaloniki, Grecia)
dc.rightsacceso abierto
dc.subjectMasonry buildingtechniques
dc.subjectSeismic vulnerability assessment
dc.subjectCultural Heritage
dc.subjectBasilica del Salvador
dc.subjectSeismic isolation
dc.titleKinematic limit analysis of Basilica del Salvador, a significant example of the neo-gothic architecture in Santiago, Chile
dc.typecomunicación de congreso
sipa.codpersvinculados53086
sipa.codpersvinculados1084480
sipa.codpersvinculados1010864
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
16ECEE-Palazzi-et-al-Kinematic-limit-analysis-of-Basilica-del-Salvador.pdf
Size:
1.87 MB
Format:
Adobe Portable Document Format
Description: