dc.description.abstractThe Energy Dispersive X-ray Diffraction (EDXD) proved to be an interesting alternative to its conventional Angular Dispersive counterpart (ADXD) each time the in situ measurements are of concern. Indeed, although its resolution is lower than that of ADXD, nevertheless it may allow a very accurate determination of even minimal changes of crystalline powders lattice parameters, thanks to several advantages it exhibits with respect to ADXD. Among these advantages, discussed in the paper, the main is that no motion is required upon diffraction pattern collection. However, the reliability of EDXD results may be compromised by the presence of an electronic noise that, along with a broadening of the Bragg peaks, may induce a shift of their positions. To evaluate the magnitude of such shift and, therefore, the level of confidence in determining the lattice parameters, a systematic study of the disturbance due to the electronic noise is reported. (C) 2009 Elsevier B.V. All rights reserved.
dc.fechaingreso.objetodigital03-04-2024
dc.format.extent7 páginas
dc.fuente.origenWOS
dc.identifier.doi10.1016/j.nima.2009.08.073
dc.identifier.eissn1872-9576
dc.identifier.issn0168-9002
dc.identifier.urihttps://doi.org/10.1016/j.nima.2009.08.073
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/77053
dc.identifier.wosidWOS:000273240800011
dc.information.autorucIngeniería;Escarate P;S/I;14884
dc.issue.numero2
dc.language.isoen
dc.nota.accesocontenido parcial
dc.pagina.final572
dc.pagina.inicio566
dc.publisherELSEVIER
dc.revistaNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
dc.rightsacceso restringido
dc.subjectNoise
dc.subjectEnergy resolution
dc.subjectX-ray
dc.subjectCATHODE MATERIAL
dc.subjectPILE-UP
dc.subjectLIQUIDS
dc.subjectSPEED
dc.subject.ods11 Sustainable Cities and Communities
dc.subject.odspa11 Ciudades y comunidades sostenibles
dc.titleEffect of disturbance induced by the electronic noise on the Energy Dispersive X-ray Diffraction patterns collection
dc.typeartículo
dc.volumen610
sipa.codpersvinculados14884
sipa.indexWOS
sipa.indexScopus
sipa.trazabilidadCarga SIPA;09-01-2024
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2024-04-03. Effect of disturbance induced by the electronic noise on the Energy Dispersive X-ray Diffraction patterns collection.pdf
Size:
2.78 KB
Format:
Adobe Portable Document Format
Description: