Thermal and lighting perception in four fully glazed office buildings in Santiago, Chile

dc.contributor.authorVásquez Z., Claudio
dc.contributor.authorEncinas Pino, Felipe
dc.contributor.authorPrieto Hoces, Alejandro
dc.contributor.authorAguirre Núñez, Carlos Andrés
dc.date2020-09-03
dc.date.accessioned2020-09-02T12:24:10Z
dc.date.issued2013
dc.date.updated2020-09-01T14:37:30Z
dc.description.abstractThis paper is part of a general research project whose main objective is to establish a baseline for post-occupancy energy consumption and indoor environmental quality for office buildings in Santiago, Chile. This study aims at understanding how architectonical variables relate to, and can even determine, user comfort perception. Thus, one-year continuous monitoring in several floors at four office buildings was performed and seasonal surveys were completed. Survey participants were asked a series of questions regarding spatial orientation and comfort perception in their workspace. The data from the comfort survey and onsite measurements such as season of the year, case study, type of workspace and possibility of an outdoor view from the workstation were contrasted with the components obtained by a Principal Component Analysis (PCA). Three components were selected from the PCA, and three Maps of Perception (MP) were produced. These maps were then analyzed and interpreted so as to obtain information on the general perception of thermal and lighting comfort at workspaces within several office buildings in Santiago.
dc.description.version2020-09-03
dc.identifier.doi10.3233/FDE-130007
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/43333
dc.identifier.urihttps://doi.org/10.3233/FDE-130007
dc.information.autorucEscuela de arquitectura ; Vásquez Z., Claudio ; 0000-0001-5962-2291 ; 82699
dc.information.autorucEscuela de arquitectura ; Encinas Pino, Felipe ; 0000-0002-9428-3907 ; 10414
dc.information.autorucEscuela de arquitectura ; Prieto Hoces, Alejandro ; 0000-0003-3386-7682 ; 143667
dc.information.autorucEscuela de construcción civil ; Aguirre Núñez, Carlos Andrés ; 0000-0001-7556-8352 ; 7355
dc.issue.numero1-2
dc.language.isoen
dc.pagina.final51
dc.pagina.inicio31
dc.revistaJournal of Facade Design and Engineeringes_ES
dc.rightsacceso abierto
dc.subjectOffice buildingses_ES
dc.subjectThermal comfortes_ES
dc.subjectArchitectural designes_ES
dc.subject.ddc725.23
dc.subject.deweyArquitecturaes_ES
dc.titleThermal and lighting perception in four fully glazed office buildings in Santiago, Chilees_ES
dc.typeartículo
dc.volumen1
sipa.codpersvinculados82699
sipa.codpersvinculados10414
sipa.codpersvinculados143667
sipa.codpersvinculados7355
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
fde_2013_1-1,2_FDE0007.pdf
Size:
1.21 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description: