Optical surface monitoring and pillow positioning configuration for complex system's set-up

dc.contributor.advisorHäring, Peter, 1965-
dc.contributor.advisorSánchez Nieto, Beatriz
dc.contributor.authorLoreto Javiera Godoy Solís
dc.contributor.otherPontificia Universidad Católica de Chile. Facultad de Física
dc.date.accessioned2018-01-11T13:07:47Z
dc.date.available2018-01-11T13:07:47Z
dc.date.issued2017
dc.descriptionTesis (Master in Medical Physics)--Pontificia Universidad Católica de Chile, 2017
dc.description.abstractOptical Surface Monitoring and Pillow Positioning Configuration for Complex System’s Set-Up: Aligning the patient’s target volume, isocenter and OARs with the linac’s isocenter can be done using certain immobilization device and imaging to adapt therapy if any variation of the tumor or patient’s body has occurred. In this investigation, a configuration of 10 pillows and Vision RT were employed to positioning the patient while it was checked by CBCT. The results show that for non-coplanar fields, Vision RT is accurate enough, with shifts less than 1º and 1mm. 4 pillows in a wedge under the head show an accurate position in the rotational axis (lessthan 1º) comparing with Vision RT and the off-set values given by the CBCT, although more pillows should be necessary for thorax and pelvis plans, since the differences between both methods are in average of 5 mm and 10º. Since the image registration was made manually, there are difference between 2 CBCTs of 6 mm and 5º in average in each plan, around the same magnitude than the difference between the two methods, so the differences might be due to the fact that Vision RT matches surfaces and CBCT matches the target volume, and because the manual image registration is involved with a human error
dc.format.extentix, 67, xxxvii hojas
dc.identifier.doi10.7764/tesisUC/FIS/21430
dc.identifier.urihttps://doi.org/10.7764/tesisUC/FIS/21430
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/21430
dc.language.isoen
dc.nota.accesoContenido completo
dc.rightsacceso abierto
dc.subject.ddc610
dc.subject.deweyMedicina y saludes_ES
dc.subject.otherRadioterapia - Técnica.es_ES
dc.subject.otherTomografía computarizada de emisión.es_ES
dc.titleOptical surface monitoring and pillow positioning configuration for complex system's set-upes_ES
dc.typetesis de maestría
sipa.codpersvinculados192291
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PUC_Thesis_JavieraGodoy.pdf
Size:
5.87 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.31 KB
Format:
Item-specific license agreed upon to submission
Description: