Browsing by Author "Prieto Vasquez, Claudia Del Carmen"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemFree‐breathing 3D whole‐heart joint T1/T2 mapping and water/fat imaging at 0.55 T(2024) Si, Dongyue; Crabb, Michael G.; Kunze, Karl P.; Littlewood, Simon J.; Prieto Vasquez, Claudia Del Carmen; Botnar, René M.To develop and validate a highly efficient motion compensated free-breathingisotropic resolution 3D whole-heart joint T 1 /T2 mapping sequence with anatomicalwater/fat imaging at 0.55 T.Methods: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquirethree interleaved water/fat volumes with inversion-recovery preparation, no prepara-tion, and T 2 preparation, respectively. Image navigators were used to facilitate nonrigidmotion-compensated image reconstruction. T1 and T2 maps were jointly calculated bya dictionary matching method. Validations were performed with simulation, phantom,and in vivo experiments on 10 healthy volunteers and 1 patient. The performance ofthe proposed sequence was compared with conventional 2D mapping sequences includ-ing modified Look-Locker inversion recovery and T2 -prepared balanced steady-SSFPsequence.Results: The proposed sequence has a good T1 and T2 encoding sensitivity in simula-tion, and excellent agreement with spin-echo reference T 1 and T2 values was observedin a standardized T1 /T2 phantom (R2 = 0.99). In vivo experiments provided good-qualityco-registered 3D whole-heart T1 and T2 maps with 2-mm isotropic resolution in ashort scan time of about 7 min. For healthy volunteers, left-ventricle T1 mean andSD measured by the proposed sequence were both comparable with those of modi-fied Look-Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left-ventricle T2 mean and SD measured by theproposed sequence were both slightly lower than those of T2 -prepared balanced SSFP(53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). MyocardialT 1 and T2 in the patient measured by the proposed sequence were in good agreementwith conventional 2D sequences and late gadolinium enhancement.Conclusion: The proposed sequence simultaneously acquires 3D whole-heart T1 and T2mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7-min scan.Further investigation in patients with cardiovascular disease is now warranted
- ItemInversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order(Springer Science and Business Media B.V., 2024) Craft, J.; Weber, J.; Li;Y.; Cheng, J.Y.; Diaz , N.; Kunze, K.P.; Schmidt, M.; Grgas, M.; Weber, S.; Tang, J.; Parikh, R.; Onuegbu, A.; Yamashita, A.-M.; Haag, E.; Fuentes, D.; Czipo, M.; Neji, R.; Espada, C.B.; Prieto Vasquez, Claudia Del Carmen; Botnar, Rene MichaelContrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using.15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52–0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR. Graphical Abstract: (Figure presented.)