We addressed comprehensively the performance of Shortest-Path HARP Refinement (SP-HR), SinMod, and DENSEanalysis using 2D slices of synthetic CSPAMM and DENSE images with realistic contrasts obtained from 3D phantoms. The three motion estimation techniques were interrogated under ideal and no-ideal conditions (with MR induced artifacts, noise, and through-plane motion), considering several resolutions and noise levels. Under noisy conditions, and for isotropic pixel sizes of 1.5 mm and 3.0 mm in CSPAMM and DENSE images respectively, the nRMSE obtained for the circumferential and radial strain components were 10.7 +/- 10.8% and 25.5 +/- 14.8% using SP-HR, 11.9 +/- 2.5% and 29.3 +/- 6.5% using SinMod, and 6.4 +/- 2.0% and 18.2 +/- 4.6% using DENSEanalysis. Overall, the results showed that SP-HR tends to fail for large tissue motions, whereas SinMod and DENSEanalysis gave accurate displacement and strain field estimations, being the last which performed the best.
Registro Sencillo
Registro Completo
Autor | Mella, Hernan Mura, Joaquin Sotelo, Julio Uribe, Sergio |
Título | A comprehensive comparison between shortest-path HARP refinement, SinMod, and DENSEanalysis processing tools applied to CSPAMM and DENSE images |
Revista | Magnetic resonance imaging |
ISSN | 0730-725X |
ISSN electrónico | 1873-5894 |
Volumen | 83 |
Página inicio | 14 |
Página final | 26 |
Fecha de publicación | 2021 |
Resumen | We addressed comprehensively the performance of Shortest-Path HARP Refinement (SP-HR), SinMod, and DENSEanalysis using 2D slices of synthetic CSPAMM and DENSE images with realistic contrasts obtained from 3D phantoms. The three motion estimation techniques were interrogated under ideal and no-ideal conditions (with MR induced artifacts, noise, and through-plane motion), considering several resolutions and noise levels. Under noisy conditions, and for isotropic pixel sizes of 1.5 mm and 3.0 mm in CSPAMM and DENSE images respectively, the nRMSE obtained for the circumferential and radial strain components were 10.7 +/- 10.8% and 25.5 +/- 14.8% using SP-HR, 11.9 +/- 2.5% and 29.3 +/- 6.5% using SinMod, and 6.4 +/- 2.0% and 18.2 +/- 4.6% using DENSEanalysis. Overall, the results showed that SP-HR tends to fail for large tissue motions, whereas SinMod and DENSEanalysis gave accurate displacement and strain field estimations, being the last which performed the best. |
Derechos | acceso restringido |
DOI | 10.1016/j.mri.2021.07.001 |
Enlace | |
Id de publicación en WoS | WOS:000697019700002 |
Palabra clave | Tagging MRI CSPAMM DENSE MRI Cardiac MRI Cardiac strain HARP SP-HR SinMod DENSEAnalysis |
Tema ODS | 03 Good Health and Well-being |
Tema ODS español | 03 Salud y bienestar |
Tipo de documento | artículo |