Differential scanning calorimetry (DSC) was used to determine the oil uptake of commercial frozen par-fried potatoes after frying at 180 degrees C in colza/soybean oil. The enthalpy and temperature range of the crystallization peak for the pure frying oil were 47.2 J/g and -44 to -50 degrees C, respectively. DSC was performed by cooling samples of crust and core of fried potatoes from 10 to -60 degrees C at 1 degrees C/min and the oil content calculated from the peak area. The crust contained almost 6 times as much oil as the central core (23.6% vs 4%, dry weight basis), as visualized by light microscopy. Only 87% of the oil in the intact crust can be removed by solvent extraction, the rest being extractable only after grinding. Deviation between DSC and Soxtec extraction methods was less than 3%. The DSC method is fast, specific, and reliable, does not use solvents, requires smaller samples (<100 mg) than conventional solvent extraction methods, and can also detect freezable water.
Registro Sencillo
Registro Completo
Autor | Aguilera, JM Gloria, H |
Título | Determination of oil in fried potato products by differential scanning calorimetry |
Revista | JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY |
ISSN | 0021-8561 |
Volumen | 45 |
Número de publicación | 3 |
Página inicio | 781 |
Página final | 785 |
Fecha de publicación | 1997 |
Resumen | Differential scanning calorimetry (DSC) was used to determine the oil uptake of commercial frozen par-fried potatoes after frying at 180 degrees C in colza/soybean oil. The enthalpy and temperature range of the crystallization peak for the pure frying oil were 47.2 J/g and -44 to -50 degrees C, respectively. DSC was performed by cooling samples of crust and core of fried potatoes from 10 to -60 degrees C at 1 degrees C/min and the oil content calculated from the peak area. The crust contained almost 6 times as much oil as the central core (23.6% vs 4%, dry weight basis), as visualized by light microscopy. Only 87% of the oil in the intact crust can be removed by solvent extraction, the rest being extractable only after grinding. Deviation between DSC and Soxtec extraction methods was less than 3%. The DSC method is fast, specific, and reliable, does not use solvents, requires smaller samples (<100 mg) than conventional solvent extraction methods, and can also detect freezable water. |
Derechos | acceso restringido |
DOI | 10.1021/jf960533k |
Editorial | AMER CHEMICAL SOC |
Enlace | |
Id de publicación en WoS | WOS:A1997WP00200042 |
Paginación | 5 páginas |
Palabra clave | differential scanning calorimetry oil frying fried potatoes microstructure DEEP FOODS MASS HEAT |
Tipo de documento | artículo |